T1KE3F4V

4-Door Altronix/Kisi Access and Power Integration Kit - Trove1DR1 with eFlow6NBV, ACM4

Altronix T1KE3F4V kit consists of Trove1 enclosure and TDR1 Altronix & Kisi backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger and four (4) fuse protected output access control module. This kit also accommodates one (1) Kisi Pro Controller for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

Specifications

  • eFlow6NBV Power Supply/Charger
      • Input
        • Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.5A.
        • Main Fuse: 5A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Current: 6A continuous.
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 7AH/12VDC (Up to 2 within enclosure) 40AH/65AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • Input: 220VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • ACM4 Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow6NBV.
        • Input Fuse: 10A / 32V.
      • Outputs
        • Voltage: 24VDC.
        • Four (4) independently controlled fused outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs
        • Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Auxiliary power outputs (unswitched).
        • c) Any combination of the above.
      • Outputs Ratings
        • Fuses: 3A/32V.
      • Indicators (LED's)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 87 BTU/Hr.

Agency Listings

 
CE Compliant

Accessories

Name Description
LINQ2 Network Communication Module, Control, Monitor and Report Power Supply Diagnostics, Compatible with eFlow Series and MaximalF Power Supply/Chargers
WM100 Magnetic Cable Tie Mounts
WM25 Magnetic Cable Tie Mounts
WM5 Magnetic Cable Tie Mounts
MM12 Mounting Magnets, Twelve (12) Quantity per Pack
MM24 Mounting Magnets, Twenty Four (24) Quantity per Pack
MM4 Mounting Magnets, Four (4) Quantity per Pack
MM8 Mounting Magnets, Eight (8) Quantity per Pack

Dimensions & Weight

Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to two (2) 12VDC/7AH Batteries.
  • Dimensions 14.5"W x 18"H x 4.62"D (368.3 mm W x 457.2 mm H x 118 mm D).
  • 1", 3/4" and 1 1/2" knockouts.
Weights (approximate):
  • Product Weigtht: 16.23 Lbs. (7.36 kg).