T2PXK7F8

8-Door Altronix/Paxton Access and Power Integration Kit - Trove2PX2 with eFlow104NB, ACM8, VR6, PDS8

Altronix T2PXK7F8 kit consists of Trove2 enclosure, TPX2 Paxton/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) fused access power controller, one (1) voltage regulator and one (1) dual input fused power distribution module.
This kit also accommodates up to eight (8) Paxton Net2 Plus modules for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

Specifications

  • eFlow104NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz, 4.5A max.
        • Main Fuse: 6.3A / 250V.
      • Outputs
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12VDC/12AH (2 within enclosure); 40 AH / 65 AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units. Prevents deep battery discharge.
  • Indicators LED
    • AC Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • ACM8 Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow104NB.
        • Main Fuse: 10A / 32V.
      • Outputs
        • Voltage: 12VDC.
        • Eight (8) 24VDC independently controlled fused outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Auxiliary power outputs (unswitched).
        • c) Any combination of the above.
        • Output Fuses: 3.5A / 32VDC.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • VR6 Voltage Regulator
      • Input/Output
        • Voltage Range: 24VDC @ 10A = Output: 12VDC @ 6A.
      • Output
        • Voltage: 12VDC regulated output.
        • Output rating: 6A max.
        • Other: Surge suppression.
      • Indicators LED
        • Input: Indicates input voltage is present.
        • Output: Indicates normal operating condition.
  • PDS8 Dual Output Power Distribution Module
      • Input
        • Voltage Range: 5VDC to 24VDC, up to 10A each, 20A total input.
        • Main Fuse Rating: 10A.
      • Outputs
        • Fuse protected outputs rated @ 3A per output, non power-limited. Total output 20A max.
        • Do not exceed the individual power supply ratings.
        • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
      • Outputs Ratings
        • Voltage Range: 4.8VDC - 24VDC.
      • Indicators (LED)
        • DC Output: Individual voltage LEDs indicate 12VDC (Green) or 24VDC (Red/Green).
      • Features
        • Multiple units may be daisy-chained to accommodate larger systems.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 113 BTU/Hr.

Agency Listings

 
CE Compliant

Accessories

Name Description
LINQ2 Network Communication Module, Control, Monitor and Report Power Supply Diagnostics, Compatible with eFlow Series and MaximalF Power Supply/Chargers
MM12 Mounting Magnets, Twelve (12) Quantity per Pack
MM24 Mounting Magnets, Twenty Four (24) Quantity per Pack
MM4 Mounting Magnets, Four (4) Quantity per Pack
MM8 Mounting Magnets, Eight (8) Quantity per Pack
WM100 Magnetic Cable Tie Mounts
WM25 Magnetic Cable Tie Mounts
WM5 Magnetic Cable Tie Mounts

Dimensions & Weight

Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weigtht: 54.3 Lbs. (24.6 kg).
  • Shipping Weigtht: 59.3 Lbs. (26.9 kg).