T3AXK77F16SDQV

16-Door Altronix/Axis Access and Power Integration Kit - Trove3V3 with (2) eFlow104NBV, (2) LINQ8ACMCB, (2) VR6, (2) PDS16CB

Altronix T3AXK77F16SDQV kit consists of Trove2 enclosure, TV3 Axis Communications/ Altronix backplane with two (2) 24VDC @ 10A power supply/charger, two (2) eight (8) PTC protected networked dual input/output access control modules, two (2) 12VDC voltage regulators and two (2) sixteen (16) PTC protected dual input/output power distribution modules. This kit also accommodates up to eight (8) A1601 or A1610 or sixteen (16) A1210 modules for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

Specifications

  • Two (2) eFlow104NBV Power Supply/Chargers
      • Input
        • Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A
        • Main Fuse: 6.5A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Current: 10A continuous.
        • Auxiliary: Class 2 power-limited @ 1A (unswitched).
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12VDC/12AH (2 within enclosure), 40AH/65AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type.
    • Failover: Upon AC loss, instantaneous.
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • Input: 220VAC is present
    • DC Output: Powered
  • Two (2) VR6 Voltage Regulators
      • Input
        • Voltage: 24VDC from eFlow104NBV.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators LED
        • Input: 24VDC is present.
        • Output: Powered.
  • Two (2) PDS16CB Dual Input Power Distribution Modules
      • Input
        • Voltage: 24VDC from eFlow104NBV and 12VDC from VR6.
        • Input PTCs: 9A.
      • Outputs
        • Voltage: 12VDC and/or 24VDC.
        • Any of the sixteen (16) power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
        • Output PTCs: 2.5A.
      • Indicators (LED)
        • DC Output: Sixteen (16) individual output LEDs.
        • Green: 12VDC
        • Red: 24VDC.
  • Two (2) LINQ8ACMCB Networked Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow104NBV and 12VDC from VR6
        • Input PTC: 9A
      • Outputs
        • PTC protected outputs
        • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
        • Individual outputs may be set to OFF position for servicing
      • Output PTCs:
        • 2.5A
  • Programming Features:
      • Eight (8) Programmable Outputs:
        • - Fail-safe, fail-secure or auxiliary outputs
        • - Input controlled or manually controlled through software
        • - High (over) and low (under) voltage and current monitoring by output
        • - Multiple outputs may be programmed to be triggered by a single input
        • - Battery back-up by output
      • Eight (8) Programmable Trigger Inputs:
        • - Normally open (NO), Normally closed (NC) or Open collector sink inputs
        • - Wet Input (5VDC - 24VDC) with 10k resistor
        • - Any combination of the above
      • Other Programmable Trigger Inputs:
        • - Monitor power supply(ies) input for voltage and current limits (high/low)
        • - Input and output current calibration, Programmable timer events
        • - Programmable user levels, Enable or disable alerts by type
        • - Programmable alert reporting delay
      • Indicators (LED)
        • Green AC LED: indicates AC trouble condition
        • Green BAT LED: indicates battery trouble condition
        • Green FACP LED: indicates FACP disconnect is triggered
        • Flashing Blue Heartbeat LED: indicates network connection
        • Individual OUT1 - OUT8 Red LEDs: indicate outputs are triggered
        • Individual Voltage LEDs: indicate 12VDC (Green) or 24VDC (Red)
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 246 BTU/Hr.

Agency Listings

 
CE Compliant

Accessories

Name Description
WM5 Magnetic Cable Tie Mounts
WM25 Magnetic Cable Tie Mounts
WM100 Magnetic Cable Tie Mounts
MM4 Mounting Magnets, Four (4) Quantity per Pack
MM8 Mounting Magnets, Eight (8) Quantity per Pack
MM12 Mounting Magnets, Twelve (12) Quantity per Pack
MM24 Mounting Magnets, Twenty Four (24) Quantity per Pack
BR1 Add-On Mounting Bracket
Trove3BWC Trove Compatible Battery/Wire Enclosure
Trove3SWC Trove Compatible Battery/Wire Enclosure

Dimensions & Weight

Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 30.12"W x 36.12"H x 7.06"D (768.1 mm W x 917.5 mm H x 179.3 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weigtht: 84.2 Lbs. (38.2 kg).
  • Shipping Weigtht: 97.5 Lbs. (44.2 kg).