Specifications
Input Power Options
AC:
- 115VAC, 60Hz, 1A (with line cord and transformer)
Trigger:
- Four (4) Door Sensor/Trigger inputs
- Four (4) Strobe “Steady” Trigger Inputs
- Four (4) Strobe “Flash” Trigger Inputs
- Four (4) “Panic/Emergency” Trigger Inputs
Output Options
- 12VDC/2.5A, 24VDC/1.25A, (30W)
- Four (4) Strobe Switched Power Outputs
- Eight (8) Aux. Power Outputs
Timer
- Alphanumeric LCD display simplifies programming.
- EE Prom memory protects against loss of programming due to power failure
- Momentary and/or Latching Events
Battery y Charging
- Type: Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous
- (Batteries are sold separately).
Indicators LED
- AC Power (Green): Input voltage is present
- DC Output (Red): 12/24VDC is on
- Trigger: Active
LINQ Technology
- Remote network management allows for device reset and monitoring
- Provides local and/or remote access to critical information via LAN/WAN
- Email and Windows Dashboard Alert notifications report real-time diagnostics
- Event log tracks history
Environmental
Temperature
- Operating: 0° C to 49° C (32° F to 120° F).
- Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity
- Relative Humidity 85% +/- 5%.
BTU/Hr. (approx.):
Dimensions & Weight
Enclosure:
- Wall mount enclosure for indoor use.
- Accommodates up to two (2) 12VDC/7AH Batteries.
- Dimensions 13"W x 13.5"H x 3.25"D (330 mm W x 343 mm H x 83 mm D).
- 1/2" and 3/4" combination knockouts.
Weights (approximate):
- Product Weigtht: 8.2 Lbs. (3.7 kg).
- Shipping Weigtht: 9.2 Lbs. (4.2 kg).