MaxFit716AP

16 Door Fused Access Power Controller Kit - BC750 enclosure with AL1024ULXB2, (2) ACM8, PD16W

Altronix MaxFit716AP Access Power Controller distributes and switches power to access control systems and accessories. It converts a 115VAC, 60Hz input into sixteen (16) distributed 24VDC fuse protected outputs and sixteen (16) independently controlled 24VDC fuse protected relay outputs. Fail-Safe/Fail-Secure power outputs may be converted to dry form “C” contacts. Relays are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) relay outputs.

  • AL1024ULXB2 Power Supply/Charger
      • Input
        • Voltage: 115VAC, 60Hz, 4.2A max.
        • Input Fuse: 5A / 250V.
      • Outputs
        • Voltage: 24VDC.
        • Current: 10A @ 24VDC continuous max.
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Type: Sealed lead acid or gel type.
    • Fuse Rating: 15A/32VDC.
    • Failover: Upon AC loss, instantaneous.
    • (Batteries are sold separately).
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
  • Indicators (LED)
    • AC Input: 115VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • PD16W Power Distribution Module
      • Input
        • Voltage: 24VDC from AL1024ULXB2.
      • Outputs
        • Voltage: 24VDC.
        • Sixteen (16) fuse protected outputs.
        • 3.5A per output max.
      • Output Fuses
        • 3.5A/250V.
      • Indicators (LED)
        • Green LED: DC Output.
  • Two (2) ACM8 Dual Input Access Power Controllers
      • Input
        • Voltage: 24VDC from AL1024ULXB2.
        • Main Fuse: 10A / 32V.
      • Outputs
        • Voltage: 24VDC.
        • Eight (8) independently controlled fused outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs.
        • Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Auxiliary power outputs (unswitched).
        • c) Any combination of the above.
        • Output Fuses: 3.5A / 32VDC.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • Environmental
      • Temperature
        • Operating: 0° C to 50° C (32° F to 122° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 145 BTU/Hr.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Dimensions 16.5"W x 20.5"H x 6.25"D (419.1 mm W x 520.7 mm H x 158.8 mm D).
Weights (approximate):
  • Product Weight: 28.1 Lbs. (12.75 kg).
  • Shipping Weight: 34.1 Lbs. (15.5 kg).
Print
*Batteries sold separately
*Mounting hardware included.