T2KK3F8D

8-Door Altronix/Keyscan Access and Power Integration Kit - Trove2KA2 with eFlow6NB, ACM8CB, T16100

News Flash… Altronix lead time for all Trove Access & Power Integration kits are now 15 days max.

Altronix T2KK3F8D kit consists of Trove2 enclosure, TKA2 Keyscan/Altronix backplane with one (1) 24VDC @ 6A power supply/charger, one (1) PTC access power controller, and one (1) 16VAC transformer.
This kit also accommodate various combinations of Keyscan boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

  • eFlow6NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz, 3.5A max.
        • Input Fuse: 5A / 250V.
      • Output
        • Voltage: Factory set at 24VDC.
        • Current: 6A continuous.
        • Auxiliary: Class 2 power-limited @ 1A (unswitched).
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12AH/12VDC (2 within enclosure); 40AH/65AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous.
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
  • Indicators LED
    • Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • T16100 Transformer
      • Input
        • Voltage: 115VAC, 50/60Hz, 1A.
      • Output
        • Voltage: 16VAC/100VA. 6.25A supply current.
  • ACM8CB Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow6NB.
        • Input Fuse: 10A / 250V.
      • Outputs
        • Class 2 power-limited auto-resettable outputs.
        • Voltage: 24VDC.
        • Eight (8) independently controlled PTC outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Any combination of the above.
        • Output PTCs: 2.5A.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • Environmental
      • Temperature
        • Operating: 0° C to 50° C (32° F to 122° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 111 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 40.9 Lbs. (18.55 kg).
  • Shipping Weight: 46.9 Lbs. (21.27 kg).
Print