T2KSK38

8-Door Altronix/Keri Systems Access and Power Integration Kit - Trove2KS2 with AL600ULXB, ACMS8, VR6, PDS8

Altronix T2KSK3F8 kit consists of Trove2 enclosure, TKS2 Keri Systems/Altronix backplane with one (1) 24VDC @ 6A power supply/charger, one (1) dual output fused access power controller, one (1) voltage regulator and one (1) dual input fused power distribution module.
This kit also accommodate various combinations of Keri Systems boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

  • AL600ULXB Power Supply/Charger
      • Input
        • Voltage: 115VAC, 60Hz, 3.5A max.
        • Fusing: 5A / 250V.
      • Outputs
        • Voltage: 12VDC or 24VDC selectable.
        • Current: 6A @ 12VDC or 24VDC continuous max.
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 7AH/12VDC (Up to 2 within enclosure); 40AH/65AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
  • Indicators LED
    • Input: 115VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • ACMS8 Dual Input Access Power Controller
      • Input
        • Voltage: 24VDC from AL600ULXB and 12VDC from VR6.
        • Input Fuse: 15A / 32V.
      • Outputs
        • Voltage: 12 or 24VDC individually selectable.
        • Eight (8) selectable 12VDC - 24VDC independently controlled outputs or eight (8) independently controlled Form “C” relay outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs.
        • b) Form “C” Relays rated 28VAC or VDC @ 2.5A Rated.
        • c) Auxiliary power outputs (unswitched).
        • d) Any combination of the above.
        • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
      • Outputs Ratings
        • Fuses: 3A/32VDC.
      • Indicators (LED's)
        • Red LEDs: Outputs are triggered (relays energized).
        • Blue LED: FACP disconnect is triggered.
      • Individual voltage LEDs:
        • Green: 12VDC.
        • Red: 24VDC.
  • PDS8 Dual Input Power Distribution Module
      • Input
        • Voltage: 24VDC from AL600ULXB and 12VDC from VR6.
        • Input Fuse: 10A / 32V.
      • Outputs
        • Voltage: 12VDC or 24VDC individually selectable.
        • Output Fuses: 3A/32VDC.
      • Indicators (LED)
        • DC Output: Eight (8) individual output LEDs.
        • Green: 12VDC.
        • Red: 24VDC.
  • VR6 Voltage Regulator
      • Input
        • Voltage: 24VDC from AL600ULXB.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators LED
        • Input: 24VDC is present.
        • Output: Powered.
  • Environmental
      • Temperature
        • Operating: 0° C to 50° C (32° F to 122° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 115 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 54.3 Lbs. (24.6 kg).
  • Shipping Weight: 59.3 Lbs. (26.9 kg).

Access controllers not included

*Batteries sold separately