T2MK7F8PQ

8-Door Altronix Access and Power Integration Kit - Trove2M2 with eFlow104NB, LINQ8PD, VR6, PDS8

News Flash… Altronix lead time for all Trove Access & Power Integration kits are now 15 days max.

Altronix T2MK7F8PQ kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 24VDC @ 10A power supply/charger, Network communication module, 12VDC voltage regulator, eight (8) fuse protected output dual input/output power distribution module and eight (8) fuse protected output network managed dual input/output power distribution module. This kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
*Compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

  • eFlow104NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz. 4.5A max.
        • Input Fuse: 6.3A / 250V.
      • Outputs
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure)
    • Type: Sealed lead acid or gel type
    • Failover: Upon AC loss, instantaneous
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • AC Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • LINQ8PD Network Power Distribution Module
      • Input
        • Voltage/Current: Input 1 - 24VDC from PDS8 and Input 2 - 12VDC from PDS8.
      • Outputs
        • Output Ratings: Eight (8) fused outputs rated 3A.
        • Other: Power output(s) can be locally or remotely controlled.
        • Surge suppression.
      • Status Monitoring
        • Power Supply(ies) output voltage and load.
        • Voltage and load of each output.
        • FACP trigger and reset status.
        • Unit temperature (Celsius).
        • Power Supply AC and Battery status.
        • Battery health.
      • Indicators (LED)
        • Bat Local: Charging current status.
        • FACP Triggered / Released.
        • Input Input signal.
        • Out1 - Out8: Output status.
      • Reporting
        • Windows Dashboard Alert messages.
        • E-mail notifications.
        • Event Log tracks history.
      • Programming Features
        • Power Supply(ies) voltage and load limits (High/Low).
        • FACP trigger type (wet or dry-N.O./N.C.).
        • Input Function (FACP reset/tamper).
        • Output Reset Trigger (N.O./N.C.).
        • Battery Monitor Configuration:
        • - Battery condition (Low/Normal/Missing)
        • - Service Date
        • Configurable Output Relay(s).
        • Individual Output Configuration:
        • - Device ID
        • - Voltage and Current Limits (High/Low)
        • - FACP Trigger Setting (latching/non-latching/inactive)
        • - Battery Backup.
      • Fire Alarm Interface
        • Supervised FACP disconnect (Latching or Non-Latching).
        • FACP reset (N.C. or N.O.).
  • VR6 Voltage Regulator
      • Input
        • Voltage: 24VDC from eFlow104NB.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators LED
        • Input: 24VDC is present.
        • Output: Powered.
  • PDS8 Power Distribution Module
      • Input
        • Voltage: 12VDC from VR6 and 24VDC from eFlow104NB.
        • Input Fuse: 10A/32V.
      • Outputs
        • Voltage: 12VDC and/or 24VDC.
        • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
        • Individual outputs may be set to OFF position for servicing.
      • Outputs Ratings
        • Fuses: 3A/32V.
      • Indicators (LED)
        • DC Output: Eight (8) individual output LEDs.
        • Green: 12VDC
        • Red: 24VDC.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 87 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 40 Lbs. (18.15 kg).
  • Shipping Weight: 43.75 Lbs. (19.85 kg).
Print

Access controllers not included

*Batteries sold separately