T1BV3F4SD

4-Door Altronix/Brivo Access and Power Integration Kit - Trove1BV1 with eFlow6NB, ACM4CB, VR6

News Flash… Altronix lead time for all Trove Access & Power Integration kits are now 15 days max.

T1BV3F4SD kit consists of Trove1 enclosure and TBV1 Brivo/Altronix backplane with 12VDC or 24VDC (factory set at 24VDC) @ 6A power supply/charger, 12VDC voltage regulator, and four (4) PTC protected output access control module. This kit also accommodate various combinations of Brivo boards for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

  • eFlow6NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz.
        • Input Fuse: 5A / 250V.
      • Output
        • Voltage: 24VDC.
        • Current: 6A continuous.
        • Other: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 7AH / 12VDC (Up to 2 within enclosure). 40 AH / 65 AH (requires separate enclosure).
    • Type: Sealed lead acid or gel type.
    • Fuse Rating: 7.5A/32V.
    • Failover: Upon AC loss, instantaneous.
    • (Batteries are sold separately).
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • VR6 Voltage Regulator
      • Input
        • Voltage: 24VDC from eFlow6NB.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators (LED)
        • Input: 24VDC is present.
        • Output: Powered.
  • ACM4CB Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow6NB.
        • Input Fuse: 10A / 32V.
      • Outputs
        • Voltage: 24VDC.
        • Four (4) independently controlled Fail-Safe and/or
        • Fail-Secure 2.0A power outputs.
        • Four (4) auxiliary power outputs (unswitched).
      • Outputs Ratings
        • Output PTCs are rated 2A each.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 12VDC: 40 BTU/Hr.
        • 24VDC: 77 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Dimensions 14.5"W x 18"H x 4.62"D (368.3 mm W x 457.2 mm H x 118 mm D).
  • 1", 3/4" and 1 1/2" knockouts.
Weights (approximate):
  • Product Weight: 16.23 Lbs. (7.36 kg).
  • Shipping Weight: 20.23 Lbs. (9.07 kg).