  • eFlow104NB Power Supply/Charger
      • Input
        • Voltage: 120VAC, 60Hz, 4.5A max.
        • Input Fuse: 6.3A / 250V.
      • Output
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Type: Sealed lead acid or gel type.
    • Fuse Rating: 10A @ 32VDC.
    • Failover: Upon AC loss, instantaneous.
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
  • Indicators LED
    • AC Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • ACM8 Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow104NB.
        • Main Fuse: 10A / 32V.
      • Outputs
        • Voltage: 24VDC.
        • Eight (8) independently controlled fused outputs:
        • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
        • b) Auxiliary power outputs (unswitched).
        • c) Any combination of the above.
        • Eight (8) auxiliary power outputs (unswitched).
        • Output Fuses: 3.5A/250V.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • ACM4 Access Power Controller
      • Input
        • Voltage: 24VDC from eFlow104NB.
        • Main Fuse: 10A/320V.
      • Outputs
        • Voltage: 24VDC.
        • Four (4) independently controlled 2.5A outputs:
        • a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
        • b) Four (4) dry form “C” 5A rated relay outputs.
        • c) Any combination of the above.
        • Four (4) auxiliary power outputs (unswitched).
        • Output Fuses: 3A / 32VDC.
      • Indicators (LED)
        • Red LEDs: Outputs are triggered (relays energized).
        • Green LED: FACP disconnect is triggered.
  • PD8UL Power Distribution Module
      • Input
        • Voltage: 24VDC from eFlow104NB.
      • Outputs
        • Voltage: 24VDC.
        • Eight (8) fuse protected outputs.
        • 3.5A per output max.
        • Output Fuses: 3.5A/250V.
      • Indicators (LED)
        • Green LED: DC Output.
  • Environmental
      • Temperature
        • Operating: 0° C to 50° C (32° F to 122° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 131 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
Enclosure:
  • Wall mount enclosure for indoor use.
  • Dimensions 21.5"W x 27.25"H x 6.5"D (546.1 mm W x 692.15 mm H x 165.1 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 54.7 Lbs. (24.8 kg).
  • Shipping Weight: 59.7 Lbs. (27.1 kg).
Print

Access controllers not included

*Batteries sold separately