T3M77CK1Q

16-Door Altronix/Mercury Access and Power Integration Wired Networked Kit - Trove3M3 with (2) eFlow104NB, (2) LINQ8ACM, (2) VR6, (2) LINQ8PD, RSB2, wire harnesses and finger duct

Altronix T3M77CK1Q is a 16-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T3M77CK1Q accommodates up to one (1) Intelligent Dual Reader Controller and seven (7) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.

*Also compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt.

  • Two (2) eFlow104NB Power Supply/Chargers
      • Input
        • Voltage: 120VAC, 60Hz, 9A max.
        • Main Fuse: 6.3A / 250V.
      • Output
        • Voltage: 24VDC @ 10A.
        • Auxiliary: 1A (unswitched).
        • Protection: Overvoltage protection. Filtered and regulated.
  • Battery Charging
    • Capacity: 12VDC/12AH (4 within enclosure); 40AH/65AH (requires separate enclosure).
    • Type: Sealed lead acid or gel type.
    • Failover: Upon AC loss, instantaneous.
    • (Batteries are sold separately).
  • Fire Alarm Disconnect
    • Supervised: Latching or non-latching.
    • EOL: 10K Resistor.
  • Supervision
    • AC Failure: Form “C” contacts.
    • Battery: Form “C” contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
  • Indicators LED
    • AC Input: 120VAC is present.
    • DC Output: 24VDC is present.
    • Battery: Discharged or not connected.
  • Two (2) LINQ8ACM Networked Access Power Controllers
      • Input
        • Voltage: 24VDC from eFlow104NB and 12VDC from VR6
        • Input Fuses: 15A/32V
      • Outputs
        • Fuse protected outputs
        • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2
        • Individual outputs may be set to OFF position for servicing
      • Output Fuses:
        • 3A/32V
  • Programming Features:
      • Eight (8) Programmable Outputs:
        • - Fail-safe, fail-secure or auxiliary outputs
        • - Input controlled or manually controlled through software
        • - High (over) and low (under) voltage and current monitoring by output
        • - Multiple outputs may be programmed to be triggered by a single input
        • - Battery back-up by output
      • Eight (8) Programmable Trigger Inputs:
        • - Normally open (NO), Normally closed (NC) or Open collector sink inputs
        • - Wet Input (5VDC - 24VDC) with 10k resistor
        • - Any combination of the above
      • Other Programmable Trigger Inputs:
        • - Monitor power supply(ies) input for voltage and current limits (high/low)
        • - Input and output current calibration, Programmable timer events
        • - Programmable user levels, Enable or disable alerts by type
        • - Programmable alert reporting delay
      • Indicators (LED)
        • Green AC LED: indicates AC trouble condition
        • Green BAT LED: indicates battery trouble condition
        • Green FACP LED: indicates FACP disconnect is triggered
        • Flashing Blue Heartbeat LED: indicates network connection
        • Individual OUT1 - OUT8 Red LEDs: indicate outputs are triggered
        • Individual Voltage LEDs: indicate 12VDC (Green) or 24VDC (Red)
  • Two (2) VR6 Voltage Regulators
      • Input
        • Voltage: 24VDC from eFlow104NB.
      • Output
        • Voltage: 12VDC.
        • Current: 6A continuous.
        • Other: Surge suppression.
      • Indicators LED
        • Input: 24VDC is present.
        • Output: Powered.
  • Two (2) LINQ8PD Network Power Distribution Modules
      • Input
        • Voltage: 24VDC from eFlow104NB and 12VDC from VR6
        • Input Fuses: 15A/32V
      • Outputs
        • Output Ratings: Fused outputs rated 3A/32V
        • Other: Power output can be locally or remotely controlled
        • Surge suppression
      • Status Monitoring
        • Power Supply output voltage and load, Voltage and load of each output
        • FACP trigger and reset status, Unit temperature (Celsius)
        • Power Supply AC and Battery status, Battery health
      • Reporting:
        • Windows Dashboard Alert messages
        • E-mail notifications, Event Log tracks history
      • Programming Features:
        • Power Supply(ies) voltage and load limits (High/Low)
        • FACP trigger type (wet or dry-NO/NC)
        • Input Function (FACP reset/tamper)
        • Output Reset Trigger (NO/NC)
        • Battery Monitor Configuration:
        • - Battery condition (Low/Normal/Missing)
        • - Service Date
        • Configurable Output Relay(s).
        • Individual Output Configuration:
        • - Device ID
        • - Voltage and Current Limits (High/Low)
        • - FACP Trigger Setting (latching/non-latching/inactive)
        • - Battery Backup
      • Fire Alarm Interface:
        • Supervised FACP disconnect (Latching or Non-Latching)
        • FACP reset (NC or NO)
  • Environmental
      • Temperature
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
      • Relative Humidity
        • Relative Humidity: 85% +/- 5%.
      • BTU/Hr. (approx.):
        • 289 BTU/Hr.
 
CE Compliant
 
Components of this Trove kit are UL Listed sub-assemblies. Please refer to the corresponding Sub-Assembly Installation Guides for further information. Sub-assembly components of this kit can be found under the "Kit Contents" tab.
 
TAA Compliant
 
NDAA Compliant
 
BAA Compliant
Enclosure:
  • Wall mount enclosure for indoor use.
  • Accommodates up to four (4) 12VDC/12AH Batteries.
  • Dimensions 30.12"W x 36.12"H x 7.06"D (768.1 mm W x 917.5 mm H x 179.3 mm D).
  • 3/4" and 1" combination knockouts.
Weights (approximate):
  • Product Weight: 95.6 Lbs. (43.36 kg).
  • Shipping Weight: 108.8 Lbs. (49.35 kg).

Access controllers not included

*Batteries sold separately